+高级检索
口腔诊疗喷溅颗粒物涡旋式集除方法研究
DOI:
作者:
作者单位:

作者简介:

通讯作者:

基金项目:


Study on the Vortex-type Collection Method of Spatter Particles in Dental Practice
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    口腔诊疗过程伴随着大量喷溅颗粒物的产生,医护人员长时间暴露于高浓度颗粒物中可能会产生职业健康问题.为了对喷溅颗粒物实施高效去除进而降低医护人员暴露风险,本研究提出了一种具有长距离、高作用效益的新型涡旋排风罩.首先采用数值模拟方法,分析涡旋排风罩的流动及颗粒物去除特性,并与传统顶吸式排风罩进行对比;继而通过分析送排风速度比、水平和垂直送风角度对涡旋排风罩轴线速度、压力分布以及颗粒物去除效率的影响,探索涡旋排风罩最佳工作条件;然后在理想气流参数情况下,分析两种排风罩对不同喷溅速度的颗粒物的控制效果,探明涡旋排风罩的应用优势.结果表明,涡旋排风罩在送排风速度比为1、水平和垂直送风角度为0°时达到最佳工作条件,颗粒物去除效率可达65.9%,优于顶吸式排风罩47%的去除效率.本研究证实了涡旋排风罩在口腔诊疗中的应用潜力,为口腔诊疗过程局部源头控制提供了新方法,对诊疗微环境防控措施的构建具有参考价值.

    Abstract:

    Dental practice procedures are accompanied by the production of large amounts of spattered particles, and prolonged exposure of healthcare workers to high concentrations of particles may lead to occupational health problems. To effectively remove spatter particles and reduce the exposure risk of medical staff, this study proposed a novel vortex exhaust hood with long-distance and high-action benefits. Numerical simulation was used to analyze the vortex exhaust hood's flow and particle removal characteristics, comparing it to the traditional top-suction exhaust hood. The optimal working conditions of the vortex exhaust hood were explored by analyzing the effects of the velocity ratio of air supply and exhaust, horizontal and vertical air supply angles on the axis velocity, pressure distribution, and particle removal efficiency of the vortex exhaust hood. Under the condition of ideal airflow parameters, the control effect of two kinds of exhaust hoods on particles with different splashing speeds was analyzed, and the application advantages of the vortex exhaust hood were explored. The results showed that the vortex hood achieved the best working conditions when the air supply and exhaust velocity ratio was 1 and the angle of horizontal and vertical air supply was 0°, respectively. The removal efficiency of particulate matter can reach 65.9%, which was better than that of 47% of the top-suction hood. This study confirms the application potential of the vortex exhaust hood in dental practice, provides a new method for local source control in dental procedures and has a reference value for the construction of prevention and control measures for the treatment micro-environment.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

艾正涛 ?,刘芳 ,邢超杰 .口腔诊疗喷溅颗粒物涡旋式集除方法研究[J].湖南大学学报:自然科学版,2025,52(7):222~232

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-07-31
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭