    摘要:

    对在风吸力作用下各种常用规格、跨度的冷弯薄壁檩条进行了大量的稳定承载力分析.分析分两部分:一是对简支C型和Z型冷弯薄壁檩条在风吸力作用下的稳定承载力分析,以确定简支檩条在风吸力作用下的稳定承载力;二是嵌套搭接的Z型冷弯薄壁连续檩条在风吸力作用下的稳定承载力分析,以确定搭接长度、跨数等因素对连续檩条在风吸力作用下稳定承载力的影响.有限元分析结果与《门式刚架轻型房屋钢结构技术规程》(CECS 102:2002)中风吸力作用下檩条的稳定承载力公式计算结果对比表明,规程中公式计算结果相对保守.据此,本文提出了简支檩条在风吸力作用下稳定承载力的实用计算公式,以及嵌套搭接的Z型连续檩条在风吸力作用下的设计方法.

    Abstract:

    The stability capacity of cold-formed purloins with conventional gauge and span was analyzed under wind uplift. The analysis was divided into two parts. The first part was performed on the stability capacity of C-and Z-shaped simply supported purloins, while the other was performed on the stability capacity of Z-shaped continuous purloins with lapped connections, which was affected by the length of lapped connection, number of spans and so on. The comparison indicates that the formula of specification is considered to be conservative between the results of finite element method and the results of design formula in technical specification for steel structure of light-weight buildings with gabled frames(CECS 102:2002). According to the above analysis, applicable design formula and methods for simply supported purloins and continuous purloins with lapped connections under wind uplift were proposed.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

宋晓光,张其林,刘沈如.风吸力下冷弯薄壁檩条稳定承载力分析和设计建议[J].湖南大学学报:自然科学版,2010,37(8):17~23

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭