+高级检索
燃气锅炉直接接触式节能装置设计模型研究
DOI:
作者:
作者单位:

作者简介:

通讯作者:

基金项目:


Investigation of the Design Model in Direct-contact Economizer for Gas Boiler
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    针对燃气锅炉排烟余热回收利用问题研发了一种新型直接接触式降温减湿节能装置,装置内部设置了填料段以强化传热传质效果.为建立和完善节能装置设计方法,对其填料段内的传热传质过程和设计模型进行了分析研究,以烟气温度tg作为自变量,建立了包含Lewis数Le和主体烟气湿比热CH、烟气水相界面处烟气湿比热CHi的求解填料段传热传质微分方程组,改进了填料段内传热传质过程参数分布及填料段高度的数值计算方法,数值计算结果与试验数据吻合良好,表明所改进的计算方法可应用于新型节能装置的设计与分析.

    Abstract:

    A new direct-contact dehumidifying economizer was developed, in which the packed mass was set for the recovery of waste heat in the flue gas exhausted from gas-fired boiler. An investigation of the heat and mass transfer process in the packed mass section and the design model was carried out to build and improve the economizer designing method. A set of differential equations were developed in which the flue gas temperature tg was used as an independent variable and the Lewis Number Le, the wet specific heat CH of mainstream flue gas and CHi of the flue gas on the phase interface between the flue gas and water were included. The differential equation set can be used to calculate the parameter distribution in the heat and mass transfer process in the packed mass section and the packed mass section height. The calculation results agree well with the experimental measurement. This has proved that the calculation method developed can be applied in the design and analysis of the new direct-contact dehumidifying economizer.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

姜小敏,孙培雷,凌志光,陈闵叶.燃气锅炉直接接触式节能装置设计模型研究[J].湖南大学学报:自然科学版,2012,39(4):48~52

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。