+高级检索
阴离子交换膜无电压下分离水中磷酸盐的研究
DOI:
作者:
作者单位:

作者简介:

通讯作者:

基金项目:


Study on the Removal of Phosphate from Aqueous Solution Using Anion-exchange Membrane without Supplying Electrical Potential
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    基于Donnan分离原理,采用阴离子交换膜无电压下分离去除水中磷酸盐. 结果表明:当原水磷酸盐初始质量浓度为2.0 mg/L(0.064 5 mmol/L),受体液NaCl浓度为0.1 mol/L,给体液流量为5.0 mL/min时,磷酸盐的去除率为70.0 %. 降低给体液初始pH值至3.0,给体液磷酸盐出水浓度远高于给体液初始pH值为5.0~9.0的浓度,去除率仅为43.5 %. 在所试共存离子(Cl-,HCO-3和SO2-4)浓度范围内,其对磷酸盐的分离去除效果影响不大. 采用Na2SO4作为受体液时,磷酸盐的去除效果大大降低. 降低受体液NaCl浓度,对磷酸盐的分离去除效果影响不大,但受体液中磷酸盐的浓度明显降低. 给体液流量由2.5 mL/min增加至10.0 mL/min,磷酸盐的去除率由84.3 %下降至61.1 %.

    Abstract:

    The removal of phosphate from aqueous solution using the anion-exchange membrane was investigated without supplying electrical potential based on Donnan dialysis principle. The results showed that the removal efficiency of phosphate achieved 70.0 % under the conditions of influent phosphate of 2.0 mg/L(0.064 5 mmol/L), the NaCl concentration of 0.1 mol/L in the receiver solution, the flow rate of the feed solution of 5.0 mL/min. Decreasing the initial pH of the feed solution to 3.0, the phosphate concentration outlet in the feed solution was much higher than that with the initial pH of 5.0~9.0,and the removal efficiency of phosphate was only 43.5 %. In the tested concentration range, the accompanying anions (Cl-,HCO-3 and SO2-4) had little effect on the removal of phosphate. Using Na2SO4 solution as the receiver phase, the removal of phosphate greatly reduced. Decreasing the NaCl concentration in the receiver solution had little influence on the transport of phosphate, but the concentration of phosphate in the receiver solution decreased significantly. Increasing the flow rate of the feed solution from 2.5 mL/min to 10.0 mL/min , the removal efficiency of phosphate decreased obviously from 84.3 % to 61.1 %.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

陈世洋 ,施周 ,谢德华,胡远来.阴离子交换膜无电压下分离水中磷酸盐的研究[J].湖南大学学报:自然科学版,2012,39(5):13~17

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭