+高级检索
建筑围护结构建造过程能源消耗火用分析评价
DOI:
作者:
作者单位:

作者简介:

通讯作者:

基金项目:


Exergy Assessment of the Energy Consumption of Building Envelope Construction
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    建筑围护结构所需的建材从生产制造阶段、运输阶段到现场施工建造阶段都将消耗大量的能源,针对这3个阶段,提出了围护结构建造过程能耗及火用耗的计算方法,并提出火用能比的概念用来评价建筑能源利用的可持续性.以湖南地区某研发中心为研究对象,对其围护结构建造过程能耗进行定量分析,结果表明:围护结构建造过程能耗主要来自于建材生产阶段,其中混凝土及其砌块单位建筑面积生产能耗最大,约占整个生产阶段能耗的44%,其次为钢材,占比约41%;钢材单位建筑面积生产火用耗最大,达到整个生产阶段火用耗的48%左右,混凝土及其砌块占比38%左右.从火用能比角度分析,钢材最大,为0.92,水泥最小,为0.59.整个围护结构建造过程火用能比为0.79.结果可为研究“烂尾楼”能耗现状提供参考.提出的火用分析评价方法可以应用于其他类似建筑,并为围护结构可持续建造提供参考.

    Abstract:

    The manufacturing stage, transport stage and on-site construction stage of building materials consume large amount of energy. Based on the three stages, the calculation method for energy and exergy consumption was presented, and the concept of exergy-energy ratio was proposed to evaluate the sustainability of building energy use. A case of a research and development center located in Hunan was analyzed. The results have shown that the energy consumption of building envelope construction mainly comes from the manufacturing stage of building materials. Unit building area energy consumed by concrete and steel accounted respectively for about 44% and 41% of the total energy consumption of building materials production. Unit building area exergy consumed by concrete and steel accounted respectively for about 38% and 48% of the total exergy consumption of building materials production. From the perspective of exergy-energy ratio, the maximum value is steel, 0.92; and the minimum is cement, 0.59. The exergy-energy ratio of building envelope construction is 0.79. The results can provide reference for the research of energy consumption resulting from “uncompleted building”. The exergy assessment method presented can be applied to other similar buildings, and can provide reference for sustainable building construction.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

龚光彩,龚思越,韩天鹤,龚子彻,李水生,杨勇.建筑围护结构建造过程能源消耗火用分析评价[J].湖南大学学报:自然科学版,2014,41(4):101~106

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭