    摘要:

    对研制的一种通过在梁内开缝并填充保温材料来阻断冷热桥实现自保温功能的过梁进行了试验分析.进行了2根实心过梁和8根自保温过梁的抗弯性能试验.试验结果表明,自保温过梁中外叶梁和内叶梁的协调工作性能良好,在正常使用极限状态下的实测最大裂缝宽度均小于短期荷载下的限值,能满足正常使用要求.同时,开缝和宽度比对初裂荷载和破坏模式基本没有影响.此外,虽然开缝导致自保温过梁承载力略小于实心过梁,但两者承载力的差值不明显.自保温过梁的传热系数值比实心过梁下降65%,热工性能明显优于实心过梁.

    Abstract:

    This study conducted a test to analyze the self-insulation lintel by filling the slit in lintel with the insulation materials to prevent the thermal bridge. Two solid lintels and eight self-insulation lintels were tested to study their flexural properties. The result shows that both the outer wythe and the inner wythe of the self-insulation lintels cooperate well with each other. The measured maximum crack width under the limit state of normal use is smaller when compared with the limit value under short-term load, so it can meet the normal requirement. In addition, the slit and width ratio of the self-insulation lintels has little effect on the initial crack load and failure mode, and because of the slit, the ultimate strength of the self-insulation lintels is slightly less than the solid lintels, while the difference is obvious. Though the heat-transferring coefficient of the self-insulation lintels decreases by 65% compared with the solid lintels, it has much better thermal performance.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

黄靓,蒋文龙,王辉,江超,黄梅梅,高小宝,王海.一种新型自保温过梁抗弯及保温性能试验分析[J].湖南大学学报:自然科学版,2015,42(1):47~52

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2015-01-27
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭