Numerical Simulation of High Damping Concrete Coupled Shear Walls with Steel Plate Concealed Bracing
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    在试验研究的基础上,用非线性有限元分析软件MSC.Marc对高阻尼混凝土带钢板暗支撑双肢剪力墙进行了低周反复荷载下的数值模拟,并分析了轴压比、配钢率、高宽比和连梁刚度等对高阻尼混凝土带钢板暗支撑双肢剪力墙承载力和变形性能的影响规律.分析结果表明,数值模拟结果和试验结果吻合较好,当轴压比大于0.4时,高阻尼混凝土钢板暗支撑双肢剪力墙的延性显著下降,相对暗支撑配钢率为0.96~6.73时,能较好地改善双肢剪力墙的极限承载力.连梁跨高比、高宽比主要影响双肢剪力墙的承载力和变形性能.研究结果对高阻尼混凝土暗支撑双肢剪力墙的地震弹塑性计算具有一定的参考价值.

    Abstract:

    Based on the existing experimental data, a finite model of HDCSW with steel plate concealed bracing under low-cycle load was established reasonably with nonlinear finite element analysis software MSC.Marc. The influence of axial compression, steel ratio, height-width ratio and span-depth ratio on the capacity and deformation performance of HDCSW with steel plate concealed bracing was analyzed systemically. If the axial compression ratio is greater than 0.4, the ductility of HDCSW with steel plate concealed bracing will be obviously decreased. When the relative ratio of the steel plate concealed bracing is between 0.96 and 6.73, it will improve the ultimate bearing capacity of HDCSW with steel plate concealed bracing. The height-width ratio and span-depth ratio have a major effect on the capacity and deformation performance. The research results of HDCSW with steel plate concealed bracings have a certain reference value with elastic-plastic calculation under seismic.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

王义俊,汪梦甫.高阻尼混凝土钢板暗支撑双肢剪力墙数值分析[J].湖南大学学报:自然科学版,2015,42(5):14~20

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2015-05-21
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭