+高级检索
新型预制装配框架混凝土梁柱节点抗震性能研究
DOI:
作者:
作者单位:

作者简介:

通讯作者:

基金项目:


Research on Seismic Behavior of a New Style Precast Concrete Beam-to Column Connection
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    采用足尺模型对比试验方法,对现浇混凝土梁柱组合件、4个新型预制混凝土装配整体式框架结构梁柱节点进行低周反复荷载试验,研究新型预制装配框架节点的破坏形态、滞回特性、骨架曲线、耗能能力等抗震性能指标.试验结果表明:通过在节点核心区设置附加钢筋,可以实现梁端塑性铰的外移.装配框架节点的滞回曲线较丰满,在加载前期等效黏滞阻尼系数较现浇节点小,但是在加载到极限荷载时,装配节点的等效黏滞阻尼系数与现浇节点基本相当乃至超过现浇节点,说明新型节点具有较好的耗能能力,能够满足抗震规范要求的“强柱弱梁,强节点弱构件”的要求.

    Abstract:

    Full-scale model test method was used to investigate the seismic behavior of cast in place beam-column assembly and four new precast concrete beam-to-column connections under low-cycle reversed loading. The estimation was given for the seismic performance of new precast connection on the basis of the failure mechanism on the beam-column connections, as well as hysteretic loops, ductility, energy dissipation, etc. The results indicate that, by setting additional reinforcement in the core area of the node, it can achieve the relocation of the plastic hinge at the end of beam. The hysteresis curve of the new precast connection is plumpy, and in the pre-load, the equivalent viscous damping coefficient was smaller than the cast in place connection. However, when loaded into the ultimate load, the equivalent viscous damping coefficient of precast connections was roughly equal and even exceeded cast in place connection. It has been shown that the new connection has a better energy dissipation capacity, and can meet the requirements of “strong column weak beam, stronger joint”.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

于建兵,郭正兴,管东芝,袁晨迪.新型预制装配框架混凝土梁柱节点抗震性能研究[J].湖南大学学报:自然科学版,2015,42(7):42~47

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2015-08-13
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。