    摘要:

    为研究在荷载-硫酸盐共同作用下聚丙烯纤维混凝土柱的偏心受压性能,对 8个 聚丙烯纤维混凝土柱和1个普通混凝土对照柱进行了偏心受压静力试验,获取了荷载-变形曲 线、荷载-钢筋应变曲线以及截面应变,分析了应力比和腐蚀时间对试件破坏形态、延性以及 峰值荷载等的影响 . 结果表明:聚丙烯纤维的加入,可有效抑制硫酸盐的侵蚀作用;峰值荷载 随应力比的增加呈先提高后降低趋势,随腐蚀时间增加亦呈先提高后降低趋势,150 d时承载 力较120 d降低了15.83%;位移延性系数随应力比的增加而减小,随腐蚀时间增加呈先增加后 降低趋势,150 d时位移延性系数较60 d降低了15.79%. 同时考虑应力比及硫酸盐对混凝土的 损伤,引入损伤因子,建立经历荷载和硫酸盐作用后的混凝土抗压强度计算公式;考虑聚丙烯 纤维混凝土抗拉强度对受拉区的贡献,采用等效矩形应力图简化计算方法,引入受拉区等效 系数,建立荷载与硫酸盐共同作用下聚丙烯纤维混凝土柱承载力计算公式;并考虑聚丙烯纤 维和硫酸盐腐蚀的影响,建立了最大裂缝宽度计算公式. 理论计算值与试验值吻合较好.

    Abstract:

    In order to investigate the eccentric compression performance of polypropylene (PP) fiber reinforced concrete column under the combined action of load-sulfate attack, an eccentric compression experimental research was carried out on eight PP fiber reinforced concrete columns and one ordinary concrete column. The loaddeformation curve, load- steel strain curve, and strain of column section were obtained, and the effect of different stress ratios and corrosion time on failure modes, ductility and peak load was analyzed. The results showed that the addition of PP fiber can effectively inhibit the sulfate corrosion. The increase of stress ratio was raised at first and then reduced with the peak load. As the corrosion time increased, the peak load increased first and then decreased with the decrease rate by 15.8% for time from 120 d to 150 d. Meanwhile, the ductility coefficient increased first and then decreased with the increase in corrosion time, while decreasing with the increase in stress ratio. And the coeffi? cient at 150 d was reduced by 15.79% compared with that at 60 d. Considering the damage caused by stress ratio and sulfate attack, a damage factor was introduced to establish the calculation formula of concrete compressive strength after the combined action of load-sulfate erosion. Furthermore, considering the contribution of tensile strength of PP fi? ber, an equivalent rectangular stress diagram was used. Finally, the equivalent coefficient of tensile zone was utilized to establish the bearing capacity formula for PP fiber reinforced concrete column under the combined action of loadsulfate attack. In addition, a maximum crack width formula concerning the influence of PP fibers and sulfate corrosion was also established. The theoretical results calculated by the above formulae agreed well with the test results.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

张广泰 ,张路杨 ,陈勇 ,姚继涛 ,陈柳灼 .荷载-硫酸盐共同作用下纤维混凝土柱受压性能[J].湖南大学学报:自然科学版,2022,49(1):102~112

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-03-04
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭