    摘要:

    为研究两边连接内加劲双钢板剪力墙的抗剪承载力,采用ABAQUS程序进行36个不同宽高比、不同高厚比的两边连接内加劲双钢板剪力墙的有限元分析. 分析结果表明,采用厚板或宽高比较大的钢板均可以使钢材达到较高的平均应力水平;峰值平均剪应力与屈服平均剪应力的比值随高厚比或宽高比变化的规律不明显,强屈比随高厚比变化介于1.17~1.21之间,随宽高比的变化介于1.16~1.21之间,平均值均为1.19;给出了宽高比为0.33~2.00、高厚比为200~750的两边连接内加劲双钢板剪力墙屈服平均剪应力计算公式;采用结构力学位移计算原理推导的理论计算公式可准确计算内加劲双钢板剪力墙的初始刚度和初始等效剪切模量. 建立了两边连接内加劲双钢板剪力墙的等效交叉杆模型,验证了等效交叉杆模型可以精准地模拟不同宽高比、不同高厚比两边连接内加劲双钢板剪力墙的屈服平均剪应力和初始刚度,表明可以采用等效交叉杆模型简化两边连接内加劲双钢板剪力墙的设计与分析.

    Abstract:

    To further study the shear capacity of double steel plate shear walls with internal stiffeners connected at two sides, the finite element analysis of 36 double steel plate shear walls with different width-depth ratios and different height thickness ratios, which are internally stiffened with two-side connections, is carried out by using ABAQUS program. The analysis results showed that the use of thick plates or plates with a larger width-depth ratio can make the steel reach a higher average stress. The ratio of peak mean shear stress to yield mean shear stress has no obvious change rule with height-thickness ratio or width-depth ratio. The variation of strain-hardening ratio with height thickness ratio is between 1.17 and 1.21, and the variation with width-depth ratio is between 1.16 and 1.21, with an average value of 1.19. The formula for calculating the yield mean shear stress of double steel plate shear walls with internal stiffeners connected at both sides is given. The theoretical calculation formula derived from the displacement calculation principle of structural mechanics can accurately calculate the initial stiffness and initial equivalent shear modulus of an internally stiffened double steel plate shear wall. In addition, the equivalent cross brace model of double steel plate shear walls with internal stiffeners connected at both sides is established. It is verified that the equivalent cross brace model can accurately simulate the yield mean shear stress and initial stiffness of double steel plate shear walls with internal stiffeners connected at both sides with different width-depth ratios and different height-thickness ratios. It is shown that the design and analysis of double steel plate shear walls with internal stiffeners connected at both sides can be simplified by using the equivalent cross brace model.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

XU Yafei, TAN Ping?,CHEN Lin, ZHOU Fulin.两边连接内加劲双钢板剪力墙抗剪承载力研究[J].湖南大学学报:自然科学版,2023,(11):120~127

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-12-04
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭