    摘要:

    室内空气品质控制目标的合理确定是解决当前多组分低浓度室内空气污染问题和营造健康舒适室内空气环境的重要前提.针对人体代谢污染和建材饰材散发污染的联合暴露条件,通过暴露实验且针对我国受试人员研究了可感受的室内空气品质的控制目标;其中,空气品质的可接受性和气味强度由受试人员投票得到.研究结果发现,未适应者与适应者对室内空气品质控制目标的要求具有显著差别.为使80%和90%的未适应者达到满意,CO2体积分数要求分别为0.11%和0.06%,TVOC质量浓度要求分别为243 μg/m3和76 μg/m3,每人所需要的新风量指标分别为6.6 L/s和19.5 L/s;同时,为使80%和90%的适应者达到满意,CO2体积分数要求分别为0.209%和0.098%,TVOC质量浓度要求分别为583 μg/m3和228 μg/m3,每人所需新风量指标分别为0.5 L/s和14.1 L/s.

    Abstract:

    Reasonable determination of indoor air quality controlled objective is an important prerequisite for solving indoor air pollution problem with multi-component and low concentration and building health and comfort indoor air environment.By combining pollution exposure conditions with human body metabolic pollutant and the pollutant emitting from building and furnishing material, the perceived indoor air quality controlled objective was studied for Chinese subjects on the basis of exposure experiments.Moreover, air quality acceptability and odor intensity were obtained by the subjects' votes.The results show that there exists obvious difference between visitors' requirement of indoor air quality controlled objective and that of occupants.in order to make 80% and 90% of the visitors satisfied, the required concentrations of carbon dioxide are 0.11% and 0.06%, required concentrations of total volatile organic compound are 243 μg/m3 and 76 μg/m3, and required per person outdoor airflow rates are 6.6 L/s and 19.5 L/s, respectively.Meanwhile, in order to make 80% and 90% of the occupants satisfied, required concentrations of carbon dioxide are 0.209% and 0.098%, required concentrations of total volatile organic compound are 583 μg/m3 and 228 μg/m3, and required per person outdoor airflow rates are 0.5 L/s and 14.1 L/s, respectively.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

王 军,龙恩深,张 旭.基于PAQ 的室内空气品质控制目标实验研究[J].湖南大学学报:自然科学版,2013,40(3):31~35

复制
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
作者稿件一经被我刊录用,如无特别声明,即视作同意授予我刊论文整体的全部复制传播的权利,包括但不限于复制权、发行权、信息网络传播权、广播权、表演权、翻译权、汇编权、改编权等著作使用权转让给我刊,我刊有权根据工作需要,允许合作的数据库、新媒体平台及其他数字平台进行数字传播和国际传播等。特此声明。
关闭