+Advanced Search

Flexural Performance and Capacity Calculation of Unreinforced UHPC Slabs
Author:
  • SU Jie1,2,CHEN Junting1,FANG Zhi1,3†,CHEN Jiaxing1,CAO Qing4,ZHOU Teng1

    SU Jie1,2,CHEN Junting1,FANG Zhi1,3†,CHEN Jiaxing1,CAO Qing4,ZHOU Teng1

    [1.College of Civil Engineering ,Hunan University, Changsha 410082, China; 2.Key Laboratory for Green & Advanced Civil Engineering Materials and Application Technology of Hunan Province (Hunan University), Changsha 410082. China; 3.Key Laboratory for Wind and Bridge Engineering of Hunan Province (Hunan University), Changsha 410082, China; 4.Guangdong Province Communications Planning & Design Institute Group Co., Ltd, Guangzhou 510507, China]
    在知网中查找
    在百度中查找
    在本站中查找
  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
    Abstract:

    To investigate the flexural performance of unreinforced ultra high performance concrete (UHPC) one-way slabs and square slabs, experimental studies were conducted on the slabs under locally applied loads at mid-span, respectively. Based on the test results from the present study and other literature, the tensile constitutive model of UHPC was proposed in which the influence of the characteristic parameters of steel fiber was included. Through the nonlinear sectional analysis on the slabs, an equation was developed for determining the reduction factor k of equivalent uniform stress in the tensile zone of the unreinforced UHPC slabs at the ultimate. According to the test and analysis results, a simplified approach for calculating the flexural capacity of unreinforced UHPC one-way and square slabs was presented. The results show that all the unreinforced UHPC one-way and square slabs experienced a tension failure governed by the tensile properties of the UHPC. Owing to the enhancement by the steel fibers in UHPC, the unreinforced UHPC slabs exhibited a ductile failure mode with significantly greater loads and deformations at the ultimate state as compared to those at the initial cracking state. Because the plasticity of UHPC in tension is not enough to ensure the formation of a fully plastic mechanism in those unreinforced UHPC square slabs, the upper bound solution from the yield line theory is unsuitable to predict the flexural capacity of the slabs. However, the lower-bound one from the static method of limit analysis can give better predictive results with a safer margin, and the feasibility of the developed simplified approaches for predicting the flexural capacity of unreinforced UHPC one-way and square slabs are verified well by the test results.

    Reference
    Related
    Cited by
Article Metrics
  • PDF:
  • HTML:
  • Abstract:
  • Cited by:
Get Citation
History
  • Online: June 05,2023